涓枃 English

Products

HomeProductsDC500V

DC500V

Cut off power supply to the battery system when a fault occurs in the power battery system. When the system pressure or current is too high, the fuse will overheat and melt, causing the system to lose power supply, avoiding further escalation of system faults and reducing the risk of accidents.
SLES-00L81

SLES-00L81

Technical Parameters:
Reference Standard:GB/T 13539.4、IEC60269-4
Rated Voltage:DC 500V
Rated Current:100A~450A
Interruting Capacity:50kA
Class of Operation:aR
※ Please refer to the model specification for details!

SLES-01L81

SLES-01L81

Technical Parameters:
Reference Standard:GB/T 13539.4、IEC60269-4
Rated Voltage:DC 500V
Rated Current:125A~550A
Interruting Capacity:50kA
Class of Operation:aR
※ Please refer to the model specification for details!

SLEV-10L55

SLEV-10L55

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:1A~50A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-18L63

SLEV-18L63

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:10A~125A
Interruting Capacity:30kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-25B72

SLEV-25B72

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:80A~200A
Interruting Capacity:30kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-32B75

SLEV-32B75

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:160A~350A
Interruting Capacity:30kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-38B80

SLEV-38B80

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:250A~500A
Interruting Capacity:30kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-51B82

SLEV-51B82

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:350A~700A
Interruting Capacity:30kA
Class of Operation:EV
※ Please refer to the model specification for details!