涓枃 English

Products

HomeProductsFuse series

Fuse series

Cut off power supply to the battery system when a fault occurs in the power battery system. When the system pressure or current is too high, the fuse will overheat and melt, causing the system to lose power supply, avoiding further escalation of system faults and reducing the risk of accidents.
SLES-00L61

SLES-00L61

Technical Parameters:
Reference Standard:GB/T 13539.4、IEC60269-4
Rated Voltage:DC 250V
Rated Current:160A~550A
Interruting Capacity:50kA
Class of Operation:aR
※ Please refer to the model specification for details!

SLES-01L61

SLES-01L61

Technical Parameters:
Reference Standard:GB/T 13539.4、IEC60269-4
Rated Voltage:DC 250V
Rated Current:200A~630A
Interruting Capacity:50kA
Class of Operation:aR
※ Please refer to the model specification for details!

SLEV-15L40

SLEV-15L40

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 250V
Rated Current:10A~100A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-18L43

SLEV-18L43

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 250V
Rated Current:16A~100A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-25B50

SLEV-25B50

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 250V
Rated Current:63A~400A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-32B53

SLEV-32B53

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 250V
Rated Current:100A~500A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-38B59

SLEV-38B59

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 250V
Rated Current:200A~500A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-51B62

SLEV-51B62

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 250V
Rated Current:300A~800A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLES-00L81

SLES-00L81

Technical Parameters:
Reference Standard:GB/T 13539.4、IEC60269-4
Rated Voltage:DC 500V
Rated Current:100A~450A
Interruting Capacity:50kA
Class of Operation:aR
※ Please refer to the model specification for details!

SLES-01L81

SLES-01L81

Technical Parameters:
Reference Standard:GB/T 13539.4、IEC60269-4
Rated Voltage:DC 500V
Rated Current:125A~550A
Interruting Capacity:50kA
Class of Operation:aR
※ Please refer to the model specification for details!

SLEV-10L55

SLEV-10L55

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:1A~50A
Interruting Capacity:20kA
Class of Operation:EV
※ Please refer to the model specification for details!

SLEV-18L63

SLEV-18L63

Technical Parameters:
Reference Standard:ISO8820-8、GB/T 31465.6
Rated Voltage:DC 500V
Rated Current:10A~125A
Interruting Capacity:30kA
Class of Operation:EV
※ Please refer to the model specification for details!

Get An Inquiry

Please feel free to send your message to us,we will contact you and provide you with the corresponding service as soon as possible, please write in English.

Website Copyright © Zhejiang XinLi Fuse Co., LTD All Rights Reserved.
Emailslfc@slfc.cnSkypeshawn-tungWhatsApp8615267773846 WeChat